HOMEPRODUCTS RAILWAY CABLES

 

1.8/3KV Single Core Medium Wall Fire Resistant Traction Cables

 

Application:

Single Core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fi xed and moving parts.

Standards:

BS 6853 -1a

DIN 5510-1 1-4

NFF 16-101 F0

BS 6387

Construction:

1.8/3KV Single Core Medium Wall Fire Resistant Traction Cables

Conductors

Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.

Flame Barrier

Mica tape.

Insulation

Electron beam crosslinkable medium wall LSZH compound.

Sheath

Electron beam crosslinkable LSZH compound.

Electrical Characteristics at 20℃:

Nominal Conductor Cross Section mm² 1.0 1.5 2.5 4.0 6.0 10 16
Maximum Conductor Resistance Ω/km 20.0 13.7 8.21 5.09 3.39 1.95 1.24
Voltage Rating KV 1.8/3

 

Nominal Conductor Cross Section mm² 25 35 50 70 95 150
Maximum Conductor Resistance Ω/km 0.795 0.565 0.393 0.277 0.21 0.132
Voltage Rating KV 1.8/3

Mechanical and Thermal Properties:

Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)

Temperature Range:-40℃ to +120℃

Dimensions And Weight:

Cable Code No. of cores& Nominal Conductor Cross
Sectional Area
No. x AWG
Nominal Diameter
of Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
FRA-MW-3S-FR-1G1.5 1×1.5 30/0.25 0.8 3.7 26
FRA-MW-3S-FR-1G2.5 1×2.5 50/0.25 0.75 3.95 35
FRA-MW-3S-FR-1G4 1×4 56/0.3 0.95 4.95 55
FRA-MW-3S-FR-1G6 1×6 84/0.3 0.90 5.35 75
FRA-MW-3S-FR-1G10 1×10 80/0.4 1.05 6.80 130
FRA-MW-3S-FR-1G16 1×16 126/0.4 1.20 8.60 190
FRA-MW-3S-FR-1G25 1×25 196/0.4 1.35 10.2 280
FRA-MW-3S-FR-1G35 1×35 276/0.4 1.55 11.7 390
FRA-MW-3S-FR-1G50 1×50 396/0.4 1.85 13.8 550
FRA-MW-3S-FR-1G70 1×70 360/0.5 1.70 15.8 720
FRA-MW-3S-FR-1G95 1×95 475/0.5 1.90 17.6 960
FRA-MW-3S-FR-1G120 1×120   1.95 20.2 1180